Call 608-833-4718 - or email order@westgard.com
Basic QC Practices, Third Edition
![]() |
Basic QC Practices, Third Edition |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
List Price:
$80.00 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Ask a question about this product | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Third Edition BASIC QC: REVISED, UPDATED, AND EXPANDED!
Thousands of laboratory professionals have made the Basic QC Practices their standard reference on laboratory quality control.
Now more than ever, Basic QC Practices is the gold standard for learning Quality Control: a concise and comprehensive introduction to the backbone of the laboratory -- statistical quality control. For healthcare pratictioners who want to implement and operate valid QC procedures, this manual is an essential reference. Praise for the First Edition"This extremely readable book delivers what it promises, and more…It is a refreshing blend of theory and practical advice that is useful for teaching, for review, and for everyday laboratory operations." "It is an ideal reference for those who want to implement and operate valid QC procedures in central laboratories or point of care testing settings… I enjoyed working through the book and visiting the Internet references. Books on quality control can be boring, this is not one such book." Table of Contents
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| CHAPTER | PAGE |
| 1. What is Quality Management | 1 |
| Introduction to Quality and Quality Management | 3 |
| 2. What's the idea behind Statistical Quality Control? | 15 |
| QC - The Idea | 17 |
| 3. How do you plot and interpret control results on a Levey-Jennings chart? | 27 |
| QC - The Levey-Jennings control chart | 29 |
| 4. How often should controls be run? | 49 |
| QC - The Frequency of Controls | 51 |
| 5. How do you QC the Total Testing Process? | 59 |
| QC - The Need for a Plan for the Total Testing Process | 61 |
| 6. How do you interpret control data using a multirule QC procedure? | 71 |
| QC - The "Westgard Rules" | 73 |
| 7. How do you interpret multilevel QC data? | 87 |
| QC - The Multirule and Multilevel Interpretation | 89 |
| 8. How do you solve out-of-control problems? | 107 |
| QC - The Out-of-Control Problem | 109 |
| 9. What documentation and QC records are required? | 121 |
| QC - The Records | 123 |
| 10. How do you assure the Quality of Quality Control? | 129 |
| QC - Doing the Right Thing Right | 131 |
| 11. What are the minimum requirements for QC? | 139 |
| QC - The Regulations | 141 |
| 12. What are control materials and what characteristics are important? | 159 |
| QC - The Materials | 161 |
| Medical Decision Levels | 170 |
| 13. What calculations do you have to perform? | 175 |
| QC - The Calculations | 177 |
| 14. What is external quality assessment? | 195 |
| QC - Exernal Quality Assessment | 197 |
| 15. What are the chances of run rejection? | 213 |
| QC - Rejection Characteristics and Power Curves | 215 |
| 16. How do you select the Right QC? | 229 |
| The Sigma-metric QC Selection Tool | 231 |
| 17. What's wrong with Equivalent QC? | 249 |
| Equivocal Quality Testing | 251 |
| 18. What's the Right Quality System? | 267 |
| Laboratory Analytical QC Plans and Quality Systems | 269 |
| 19. What about QC for other tests? | 287 |
| QC Practices for Molecular Testing | 289 |
| 20. What about pre- and post-analytical quality? | 307 |
| QC "Outside the box": Pre-analytical and Post-analytical Quality Control Strategies | 311 |
| 21. How do you do the Right QC Right? | 327 |
| Quality Conclusions: 10 Corrective Actions, 10 Quality Improvements, and 10 Steps you can take now |
329 |
| Appendix 1: CLIA'88 Quality Requirements | 345 |
| Index | 349 |
You may also be interested in this/these product(s)
Basic QC Practices Online Course
$135.00 |
"Westgard Rules" and Levey-Jennings Charts Short Course
$75.00 |
Member Login
What's New

Basic QC Practices
- Error Rates in the Total Testing Process
- Pre-Analytical and Post-Analytical QC
- QC Practices for Molecular Testing
- QC - Proficiency Testing, EQC, and Peer Groups
- QC - The Idea
- QC: The Levey-Jennings Control Chart
- QC - The Materials
- QC - The Calculations
- QC - The Chances of Rejection
- QC - The Out-of-Control Problem
- QC - The Multirule Interpretation
- QC - The Records
- QC: Levey-Jennings: Answers
- QC Calculation Problem Set
- QC Calculation Problem Set - Answers






