MEDICAL
DECISION LEVELS
These figures are quoted from Statland BE.
Clinical Decision Levels for Laboratory Tests, Second Edition
[Oradell NJ;Medical Economics Books, 1987.] with permission.
|
Test |
Units |
Reference
Interval |
Decision Levels |
|
ELECTROLYTES |
1 |
2 |
3 |
4 |
5 |
|
Calcium |
mg/dL |
9.0-10.6 |
7.0 |
11.0 |
13.5 |
|
|
|
Chloride |
mmol/L |
98-109 |
90 |
112 |
|
|
|
|
CO2 Content |
mmol/L |
23-30 |
6.0 |
20 |
33 |
|
|
|
Magnesium |
mEq/L |
1.2-2.4 |
1.2 |
2.0 |
5.0 |
|
|
|
mmol/L |
0.6-1.2 |
0.6 |
1.0 |
2.5 |
|
|
|
Phosphorus |
mg/dL |
2.5-5.0 |
1.5 |
2.5 |
5.0 |
|
|
|
Potassium |
mmol/L |
3.7-5.1 |
3.0 |
5.8 |
7.5 |
|
|
|
Sodium |
mmol/L |
138-146 |
115 |
135 |
150 |
|
|
Back to top
|
Test |
Units |
Reference
Interval |
Decision Levels |
|
METABOLITES |
1 |
2 |
3 |
4 |
5 |
|
Bilirubin |
mg/dL |
0.1-1.2 |
1.4 |
2.5 |
20 |
|
|
|
Cholesterol |
mg/dL |
150-275 |
90 |
240 |
260 |
350 |
|
|
Creatinine |
mg/dL |
0.7-1.5 |
0.6 |
1.6 |
6.0 |
|
|
|
Glucose |
mg/dL |
60-95 |
45 |
120 |
180 |
|
|
|
Iron |
ug/dL |
50-165 |
50 |
220 |
400 |
|
|
|
Triglycerides |
mg/dL |
20-180 |
40 |
150 |
400 |
|
|
|
Urea Nitrogen (BUN) |
mg/dL |
8-26 |
6 |
26 |
50 |
|
|
|
Uric acid |
mg/dL |
2.5-7.0 |
2.0 |
8.0 |
10.7 |
|
|
Back to top
|
Test |
Units |
Reference
Interval |
Decision Levels |
|
PROTEINS and ENZYMES |
1 |
2 |
3 |
4 |
5 |
|
Alanine aminotransferase |
U/L |
5-40 |
20 |
60 |
300 |
|
|
|
Albumin |
g/dL |
3.5-5.0 |
2.0 |
3.5 |
5.2 |
|
|
|
Alkaline phosphatase |
U/L |
35-120 |
50 |
150 |
400 |
|
|
|
Amylase |
Somogyi U |
60-180 |
50 |
120 |
200 |
|
|
|
Aspartate aminotransferase |
U/L |
8-40 |
20 |
60 |
300 |
|
|
|
Carcinoembryonic antigen |
ng/mL |
<2.5 |
2.5 |
10 |
20 |
|
|
|
Creatine kinase |
U/L |
10-180 |
100 |
240 |
1800 |
|
|
|
Glutamyl transferase |
U/L |
5-40 |
20 |
50 |
150 |
|
|
|
Lactate dehydrogenase |
U/L |
60-220 |
150 |
300 |
500 |
|
|
|
Total protein |
g/dL |
6.0-8.0 |
4.5 |
6.0 |
8.0 |
|
|
Back to top
|
Test |
Units |
Reference
Interval |
Decision Levels |
|
HORMONES |
1 |
2 |
3 |
4 |
5 |
|
Cortisol in plasma |
ug/dL |
7-20 @8am |
5 |
10 |
18 |
25 |
|
|
Cortisol (Free) in urine |
ug/24 hrs |
20-90 |
50 |
100 |
|
|
|
|
Follicle-stimulating hormone |
mIU/mL |
2-15 Adult M |
1 |
35 |
60 |
|
|
|
Follicular phase, Luteal phase |
|
3-15 Adult F |
|
|
|
|
|
|
17-Hydroxycorticosteroids |
mg/24 hrs |
3-10 |
3 |
15 |
20 |
|
|
|
17-Ketosteroids in urine |
mg/24 hrs |
8-20 Adult M |
20 |
25 |
40 |
|
|
|
|
5-15 Adult F |
|
|
|
|
|
|
Luteinizing hormone |
mIUL/mL |
5-25 Adult M |
1 |
50 |
100 |
|
|
|
Follicular phase |
|
5-30 Adult F |
|
|
|
|
|
|
Metanephrine in urine |
mg/24 hrs |
<1.3 |
1.3 |
2.5 |
|
|
|
|
Prolactin |
ng/mL |
1-20 M |
30 |
100 |
300 |
|
|
|
|
1-25 F |
|
|
|
|
|
|
Thyroxine |
ug/dL |
5.5-12.5 |
5 |
7 |
10 |
14 |
|
|
Vanillymandelic acid in urine |
mg/24 hrs |
<6.8 |
6.8 |
13 |
|
|
|
Back to top
|
Test |
Units |
Reference
Interval |
Decision Levels |
|
HEMATOLOGY RELATED TESTS |
1 |
2 |
3 |
4 |
5 |
|
Antithrombin-III |
% of normal |
80-120 |
50 |
75 |
|
|
|
|
Bleeding Time |
min |
2.3-9.2 |
10 |
15 |
|
|
|
|
Fibrinogen in plasma |
mg/dL |
200-400 |
30 |
100 |
500 |
|
|
|
Folate in serum |
ng/mL |
2-15 |
1.5 |
4.0 |
|
|
|
|
Hematocrit |
L/L |
0.43-0.51 M |
0.14 |
0.33 |
0.56 |
0.70 |
|
|
|
0.38-0.46 F |
|
|
|
|
|
|
Hemoglobin |
g/dL |
14-17.8 M |
4.5 |
10.5 |
17 |
23 |
|
|
|
12-15.6 F |
|
|
|
|
|
|
Mean corpuscular volume |
fL (cu u) |
84-96 |
80 |
100 |
|
|
|
|
Partial thromboplastin time |
sec |
30 |
35 |
45 |
90 |
|
|
|
Plasminogen |
% |
80-120 |
50 |
75 |
135 |
|
|
|
Platelet count |
K/uL |
150-400 |
10 |
50 |
100 |
600 |
1000 |
|
Prothrombin time |
sec |
11.5 |
14 |
16 |
30 |
|
|
|
Vitamin B12 |
pg/mL |
200-900 |
170 |
250 |
1200 |
|
|
|
White blood cell count |
K/uL |
4-11 |
0.5 |
3 |
12 |
30 |
|
Back to top
|
Test |
Units |
Theraputic
Range |
Decision Levels |
|
DRUGS |
1 |
2 |
3 |
4 |
5 |
|
Amikacin |
ug/mL |
20-30 (peak) |
10 |
20 |
32 |
|
|
|
|
1-8 (trough) |
|
|
|
|
|
|
Carbamazepine |
ug/mL |
4-12 |
4 |
9 |
14 |
|
|
|
Digoxin |
ug/mL |
0.9-2.0 |
1.0 |
1.6 |
2.5 |
|
|
|
Disopyramide |
ug/mL |
2.5-5.0 |
2.5 |
4.5 |
7.0 |
|
|
|
Ethosuximide |
ug/mL |
50-100 |
50 |
120 |
|
|
|
|
Gentamicin |
ug/mL |
6-10 (peak) |
0.5 |
2 |
6 |
12 |
|
|
|
0.5-1.5 (trough) |
|
|
|
|
|
|
Kanamycin |
ug/mL |
20-30 (peak) |
10 |
20 |
32 |
|
|
|
|
1-8 (trough) |
|
|
|
|
|
|
Lidocaine |
ug/mL |
1.5-5.0 |
1.5 |
5.0 |
7.0 |
|
|
|
Lithium |
mmol/L |
0.5-1.2 |
0.4 |
0.8 |
1.5 |
|
|
|
Phenobarbital |
ug/mL |
15-40 |
15 |
30 |
60 |
120 |
|
|
Phenytoin |
ug/mL |
10-20 |
10 |
20 |
50 |
|
|
|
Primidone |
ug/mL |
5-12 |
5 |
9 |
12 |
|
|
|
Procainamide |
ug/mL |
4-10 |
4 |
12 |
16 |
|
|
|
Quinidine |
ug/mL |
2-5 |
2 |
5 |
7 |
|
|
|
Salicylates |
ug/mL |
150-300 |
150 |
300 |
500 |
|
|
|
Theophylline |
ug/mL |
10-20 asthma |
10 |
20 |
35 |
60 |
|
|
|
5-10 neonatal apnea |
|
|
|
|
|
|
Tobramycin |
ug/mL |
6-10 (peak) |
0.5 |
2 |
6 |
12 |
|
|
|
0.5-1.5 (trough) |
|
|
|
|
|
|
Valproic acid |
ug/mL |
50-100 |
50 |
90 |
120 |
|
|
Back to top
Copyright © 2000. All rights reserved
Westgard QC, 7614 Gray Fox Trail, Madison WI 53717
Call 608-833-4718 or e-mail westgard@westgard.com
A Message from
JOW
QC Lessons | QC
Applications | Questions | Multirule
CLIA Requirements |
What's new? | Catalog
| Demo Download
Home | Glossary
| ARCHIVES | Links
| Feedback