EZ Runstm software
2002
$1495 list price
$1995 with Integrated EZ
Rulestm
Requirements:
- PC, mouse, printer
- Windows 95, 98, 2000, NT, XP
- 45 MB hard disk space
- 32 MB RAM or more
Features:
Easy Interview Mode
Multilevel, Multirule, Multistage QC Design
Built-in library of over 100 statistical control rules - the
best, most optimized "Westgard Rules" available
Complete flexibility in setting control limits - calculate mean
and SD in any of 5 ways
Traditional Levey-Jennings charts and Multicharttm view - all controls on one chart
Automatic flagging of out-of-control results
Real time decision-making - corrective
actions immediately recorded in Action Log
Supervisor privileges prevent improper
data changes.
QC Run Validation reports for inspections,
manuals, and records. You have total control over the contents
of each report, from the number of records to text comments you
can add yourself.
Help is on-screen and online. Includes
built-in tables of CLIA and other quality requirements
Special data calculations, including logarithm
transform, proportional transform, regression transform, and
signal/cutoff ratio.
Optional: integrated EZ Rulestm . Combine Automatic QC Selection with your QC charting.
Find the best rule for your test with one mouse click.
For more information:
EMAIL: ezruns@westgard.com
CALL: 608-833-4718
DOWNLOAD: the program manual and a demo.
|
EZ Runstm
Please note: This software is no longer available commercially
EZ Runstm is advanced QC Charting software.
It combines powerful features with tremendous ease-of-use. For
both the novice and the expert, EZ Runstm is the
new standard for getting QC done - and done right.
An Open System.
EZ Runstm
is not tied
to any control or any instrument or any manufacturer. You can
use it on any test, any system, and any
control materials.
With the best "Westgard
Rules". EZ Runstm has a library of over 100 single-rules
and multirule combinations (popularly known as "Westgard
Rules"), all with documented performance characteristics.
There are no illogical or unknown control rules here. EZ Runstm gives you the most advanced
QC design support so you can select the "Westgard Rules"
that are best for your test.
And complete flexibility in
setting control limits. EZ Runstm allows you to enter means and
SDs from labeled values, or assign your own. Once you've collected
enough control data, EZ Runstm can calculate the means and SDs for you,
using data from fixed intervals, moving intervals, or cumulative-to-date.
You have total control over the mean and SD that are used to
calculate control limits.
With Advanced Features only
Westgard can give you.
EZ Runstm
supports multirule,
multilevel, and multistage QC design. You can enter data from
multiple control materials running at multiple levels using multiple
control rules, all in one file, all on one screen - the MultiCharttm . These advanced QC design
features allow you to QC even the most difficult and problem-prone
tests.
EZ Runstmtm gives you complete control
over the creation of reports.
You can designate what data to include, either by record numbers
or by dates. You can specify which graphs to print, which worksheets
to include, including the Action log of corrective steps taken
after out-of-control events. Finally, you can add text comments
to each report. For complete documentation of your QC activities,
there is no better software.

Read
the Foreword, TOC, and Chapter 1 of the manual!
Compare
features with other Westgard software
Check
out the EZ Runs Service Policy
Order
the software now!
Watch
a demo!
Speak
with a customer specialist about EZ Runs |