The largest laboratory system to date has joined the Sigma VP program. Six laboratories from the Multicare health system in Washington state, USA.
"MultiCare Health System is a not-for-profit health care organization with more than 18,000 team members, including employees, providers and volunteers.
We’ve been caring for our community for well over a century, since the founding of Tacoma’s first hospital. And today, we are the largest community-based, locally governed health system in the state of Washington."
Pictured here are Bill Robertson, President and CEO of Multicare Health System; Rob roth MD, Pathologist and Board Member; Sten Westgard; Florence Chang, EVP and COO; John Baker, the guiding force of this QC project; and John Joyce, VP of Ancillary Testing (Laboratory, Imaging, Respiratory)
Allenmore Hospital
The following assays and instruments which were verified
Chemistry Assays Covington |
AR1 – CI4100 Verified |
AR2 – CI4100 Verified |
Albumin |
Six Sigma |
Six Sigma |
Alk Phos |
Six Sigma |
Six Sigma |
ALT |
Four Sigma |
Four Sigma |
Amylase |
- |
Six Sigma |
AST |
Six Sigma |
Six Sigma |
Bilirubin, Direct |
Six Sigma |
Six Sigma |
Bilirubin, Total |
Six Sigma |
Six Sigma |
Calcium |
Six Sigma |
Five Sigma |
Cholesterol |
Six Sigma |
Six Sigma |
Creatinine |
Six Sigma |
Six Sigma |
Creatinine Kinase (CK) |
- |
Six Sigma |
GGT |
- |
Six Sigma |
Glucose |
Six Sigma |
Six Sigma |
HDL |
Five Sigma |
Six Sigma |
Iron |
- |
Six Sigma |
LDH |
- |
Four Sigma |
Lipase |
- |
Six Sigma |
Magnesium |
Six Sigma |
Six Sigma |
Phosphorous |
Four Sigma |
Five Sigma |
Potassium |
Five Sigma |
Five Sigma |
Protein, Total |
Six Sigma |
Six Sigma |
Sodium |
Four Sigma |
- |
Triglycerides |
Six Sigma |
Six Sigma |
Uric Acid |
- |
Six Sigma |
Additional institutions are detailed here:
Chemistry Assays Allenmore |
AR3 – CI4100 Verified |
AR4 – CI4100 Verified |
Albumin |
Six Sigma |
Five Sigma |
Alk Phos |
Six Sigma |
Six Sigma |
ALT |
Six Sigma |
Five Sigma |
Amylase |
- |
Six Sigma |
AST |
Four Sigma |
Six Sigma |
Bilirubin, Direct |
- |
Six Sigma |
Bilirubin, Total |
Six Sigma |
Six Sigma |
Calcium |
Four Sigma |
Five Sigma |
Cholesterol |
Six Sigma |
- |
Creatinine |
Six Sigma |
Six Sigma |
Creatinine Kinase (CK) |
Six Sigma |
- |
GGT |
- |
Six Sigma |
Glucose |
Six Sigma |
Six Sigma |
HDL |
Four Sigma |
- |
Iron |
Five Sigma |
- |
Lipase |
- |
Six Sigma |
Magnesium |
Four Sigma |
- |
Phosphorous |
Six Sigma |
- |
Potassium |
- |
Five Sigma |
Protein, Total |
Six Sigma |
Six Sigma |
Triglycerides |
Six Sigma |
- |
Uric Acid |
Six Sigma |
- |
Even more institutions and instruments:
Chemistry Assays Auburn |
AR5 – CI4100 Verified |
AR6 – CI4100 Verified |
Albumin |
Four Sigma |
Five Sigma |
Alk Phos |
Six Sigma |
Six Sigma |
ALT |
Six Sigma |
Five Sigma |
Amylase |
Six Sigma |
- |
AST |
Six Sigma |
Six Sigma |
Bilirubin, Direct |
Five Sigma |
Four Sigma |
Bilirubin, Total |
Four Sigma |
Four Sigma |
Calcium |
Six Sigma |
Six Sigma |
Creatinine |
Six Sigma |
Six Sigma |
Creatinine Kinase (CK) |
Five Sigma |
Five Sigma |
GGT |
Six Sigma |
- |
Glucose |
Five Sigma |
Six Sigma |
Lipase |
Six Sigma |
Six Sigma |
Magnesium |
Six Sigma |
Six Sigma |
Potassium |
Five Sigma |
Four Sigma |
Protein, Total |
Six Sigma |
Six Sigma |
Uric Acid |
Six Sigma |
Six Sigma |
And more institutions:
Chemistry Assays Good Samaritan |
AR7 – CI8200 Verified |
AR8 – CI8200 Verified |
Albumin |
Five Sigma |
Five Sigma |
Alk Phos |
Six Sigma |
Six Sigma |
ALT |
Six Sigma |
Six Sigma |
Amylase |
Six Sigma |
Six Sigma |
AST |
Five Sigma |
Six Sigma |
Bilirubin, Direct |
Six Sigma |
Six Sigma |
Bilirubin, Total |
Six Sigma |
Six Sigma |
Calcium |
Four Sigma |
- |
Cholesterol |
Five Sigma |
Five Sigma |
Creatinine |
Six Sigma |
Six Sigma |
Creatinine Kinase (CK) |
Six Sigma |
Six Sigma |
GGT |
Six Sigma |
- |
Glucose |
Five Sigma |
Six Sigma |
HDL |
Five Sigma |
- |
Iron |
Four Sigma |
- |
LDH |
Four Sigma |
- |
Lipase |
- |
Six Sigma |
Magnesium |
Six Sigma |
Six Sigma |
Phosphorous |
Four Sigma |
- |
Potassium |
Five Sigma |
Four Sigma |
Protein, Total |
Six Sigma |
Six Sigma |
Triglycerides |
Six Sigma |
Six Sigma |
Uric Acid |
Six Sigma |
Six Sigma |
Still more institutions!!
Chemistry Assays Gig Harbor |
AR9 – CI4100 Verified |
Albumin |
Six Sigma |
Alk Phos |
Six Sigma |
ALT |
Six Sigma |
Amylase |
Six Sigma |
AST |
Six Sigma |
Bilirubin, Total |
Five Sigma |
Cholesterol |
Six Sigma |
Creatinine |
Six Sigma |
Creatinine Kinase (CK) |
Six Sigma |
Glucose |
Six Sigma |
LDH |
Four Sigma |
Lipase |
Six Sigma |
Magnesium |
Six Sigma |
Phosphorous |
Five Sigma |
Potassium |
Five Sigma |
Protein, Total |
Six Sigma |
Sodium |
Four Sigma |
Triglycerides |
Six Sigma |
Uric Acid |
Six Sigma |
And the central cord lab institution:
Chemistry Assays Tacoma |
IMC2 – C8000 Verified |
IMC6 – C16000 Verified |
IMC7 – C8000 Verified |
Albumin |
- |
Six Sigma |
- |
Alk Phos |
Six Sigma |
Six Sigma |
Six Sigma |
ALT |
Six Sigma |
Six Sigma |
Six Sigma |
Amylase |
Six Sigma |
Six Sigma |
Six Sigma |
AST |
Six Sigma |
Five Sigma |
Six Sigma |
Bilirubin, Direct |
- |
Six Sigma |
- |
Bilirubin, Total |
Six Sigma |
Six Sigma |
Six Sigma |
Calcium |
- |
Five Sigma |
- |
Cholesterol |
- |
Six Sigma |
Five Sigma |
Creatinine |
Six Sigma |
Six Sigma |
Six Sigma |
Creatinine Kinase (CK) |
Six Sigma |
Six Sigma |
- |
GGT |
Four Sigma |
- |
- |
Glucose |
Six Sigma |
Six Sigma |
Six Sigma |
HDL |
- |
Six Sigma |
Six Sigma |
Iron |
Four Sigma |
- |
Six Sigma |
LDH |
Four Sigma |
- |
- |
Lipase |
Six Sigma |
Six Sigma |
Six Sigma |
Magnesium |
Six Sigma |
Six Sigma |
Six Sigma |
Phosphorous |
Four Sigma |
Four Sigma |
Four Sigma |
Potassium |
Four Sigma |
Four Sigma |
- |
Protein, Total |
Six Sigma |
Six Sigma |
Six Sigma |
Triglycerides |
- |
Six Sigma |
Six Sigma |
Uric Acid |
Six Sigma |
Six Sigma |
Six Sigma |
More data, now on immunoassay:
Immunoassay Covington |
AR1 – CI4100 Verified |
TSH |
Four Sigma |
Immunoassays at Good Samaritan:
Immunoassay Good Samaritan |
AR7 – CI8200 Verified |
AR8 – CI8200 Verified |
TSH |
Four Sigma |
Four Sigma |
Immunoassay at Gig Harbor:
Immunoassay Gig Harbor |
AR9 – CI4100 Verified |
TSH |
Six Sigma |
Immunoassay at Tacoma:
Immunoassay Tacoma |
IMC6 – C16000 Verified |
TSH |
Five Sigma |
Hematology at Auburn:
Hematology Assays Auburn |
XN1 – XN10 Verified |
Hemoglobin |
Six Sigma |
Hematocrit |
Four Sigma |
MCV |
Six Sigma |
MCH |
Six Sigma |
Platelets |
Five Sigma |
RBC |
Six Sigma |
WBC |
Five Sigma |
Hematology at Tacoma:
Hematology Assays Tacoma |
XN2 – XN10 Verified |
XN3 – XN10 Verified |
XN4 – XN10 Verified |
Hemoglobin |
Six Sigma |
Four Sigma |
Five Sigma |
Hematocrit |
Four Sigma |
- |
- |
MCV |
Six Sigma |
Six Sigma |
Six Sigma |
MCH |
Six Sigma |
Four Sigma |
Six Sigma |
MCHC |
Five Sigma |
Four Sigma |
Five Sigma |
Platelets |
Four Sigma |
Four Sigma |
Four Sigma |
RBC |
Six Sigma |
Six Sigma |
Six Sigma |
WBC |
Six Sigma |
Six Sigma |
Six Sigma |
Reticulocyte |
Four Sigma |
- |
- |
Hematology at Allenmore:
Hematology Assays Allenmore |
XN5 – XN10 Verified |
XS2 – XS1000i Verified |
Hemoglobin |
Six Sigma |
Six Sigma |
Hematocrit |
Four Sigma |
Four Sigma |
MCV |
Six Sigma |
Six Sigma |
MCH |
Six Sigma |
Six Sigma |
MCHC |
Four Sigma |
Five Sigma |
Platelets |
Five Sigma |
Six Sigma |
RBC |
Six Sigma |
Six Sigma |
WBC |
Six Sigma |
Six Sigma |
Reticulocyte |
Four Sigma |
- |
Hematology at Good Samaritan:
Hematology Assays Good Samaritan |
XN6 – XN10 Verified |
XN7 – XN10 Verified |
Hemoglobin |
Four Sigma |
- |
MCV |
Six Sigma |
Six Sigma |
MCH |
Six Sigma |
Six Sigma |
MCHC |
- |
Four Sigma |
Platelets |
Six Sigma |
Six Sigma |
RBC |
Six Sigma |
Four Sigma |
WBC |
Six Sigma |
Six Sigma |
Hematology at Covington:
Hematology Assays Covington |
XS1 – XS1000i Verified |
XT1 – XT4000i Verified |
Hemoglobin |
Six Sigma |
Six Sigma |
Hematocrit |
Four Sigma |
Four Sigma |
MCV |
Six Sigma |
Six Sigma |
MCH |
Six Sigma |
Six Sigma |
MCHC |
Five Sigma |
Four Sigma |
Platelets |
Six Sigma |
Six Sigma |
RBC |
Six Sigma |
Six Sigma |
WBC |
Six Sigma |
Six Sigma |
Six Sigma: World Class Quality. Possible to use 3s to 3.5s limits and a minimum of controls
Five Sigma: Excellent Quality. Possible to use 3s limits or a 1:3s/2:2s/R:4s Westgard Rule
Four Sigma: Good Quality. Possible to use 1:3s/2:2s/R:4s/4:1s Westgard Rule
Auburn Medical Center
Covington Medical Center
Gig Harbor Medical Center
Good Samaritan Hospital
Tacoma General Hospital
Congratulations to the entire Multicare Laboratory Staff