Ramathibodi Hospital has succeeded in joining the Westgard Sigma Verification of Performance Program (Sigma VP). Verified since 2015, they continue to expanded their verification, including more assays, more instruments and even an additional laboratory in 2016.
In 2015 and 2016, Westgard QC was pleased to verify the performance of 29 assays on one instrument at Ramathibodi Hospital. In subsequent years, they have expanded their implementation of sigma metrics.

Following the Second National Economic and Social Development Plan (1964-1966), the Thai Government aimed to increase the number of doctors and nurses in order to meet the needs of the country. In August 1964, the Cabinet approved the plan of setting up a new medical school which would be located around the Phyathai area, Bangkok, Thailand. HM King Bhumibol Adulyadej graciously conferred the name on the new school of medicine “Ramathibodi” and laid the foundation stone for the building on December 30th, 1965. Four years later, the King came to open the new faculty of medicine on May 3rd, 1969. Apart from the Government’s fund, the Faculty was financially and academically supported by the Rockefeller Foundation from the United States of America. Since then the Faculty of Medicine Ramathibodi Hospital has been fully equipped and has provided medical education and research facilities to the public. Moreover, it serves patients in Bankgok and from all over Thailand.
http://med.mahidol.ac.th/en/aboutus/hospital-and-services-en
|
Chemistry Assays |
SDMC Alinity C (A1) Verified |
SDMC Alinity C (A2) Verified |
|
Albumin |
Six Sigma |
Six Sigma |
|
Alk Phos |
Five Sigma |
Six Sigma |
|
ALT |
Four Sigma |
Six Sigma |
|
AST |
Six Sigma |
Six Sigma |
|
Bilirubin, Direct |
Six Sigma |
Six Sigma |
|
Bilirubin, Total |
Four Sigma |
Six Sigma |
|
Calcium |
Four Sigma |
Four Sigma |
|
Chloride |
Five Sigma |
Four Sigma |
|
Cholesterol |
Six Sigma |
Six Sigma |
|
Creatinine |
Six Sigma |
Six Sigma |
|
Creatinine Kinase (CK) |
Four Sigma |
- |
|
CO2 |
Four Sigma |
Four Sigma |
|
GGT |
Six Sigma |
Six Sigma |
|
Glucose |
Six Sigma |
Five Sigma |
|
HDL |
Four Sigma |
Six Sigma |
|
LDL |
Six Sigma |
Six Sigma |
|
Magnesium |
Four Sigma |
- |
|
Phosphorous |
Four Sigma |
Six Sigma |
|
Potassium |
Six Sigma |
Six Sigma |
|
Protein, Total |
Six Sigma |
Six Sigma |
|
Sodium |
- |
Four Sigma |
|
Triglycerides |
Six Sigma |
Six Sigma |
|
Urea Nitrogen |
- |
Four Sigma |
|
Uric Acid |
Six Sigma |
Six Sigma |
|
Chemistry Assays |
SDMC Alinity C (B1) Verified |
SDMC Alinity C (B2) Verified |
|
Albumin |
Six Sigma |
Six Sigma |
|
Alk Phos |
Five Sigma |
Six Sigma |
|
ALT |
Four Sigma |
Six Sigma |
|
AST |
Six Sigma |
Six Sigma |
|
Bilirubin, Direct |
Six Sigma |
Six Sigma |
|
Bilirubin, Total |
Four Sigma |
Six Sigma |
|
Calcium |
Six Sigma |
Six Sigma |
|
Chloride |
Five Sigma |
Four Sigma |
|
Cholesterol |
Six Sigma |
Six Sigma |
|
Creatinine |
Six Sigma |
Six Sigma |
|
Creatinine Kinase (CK) |
Five Sigma |
- |
|
CO2 |
- |
Four Sigma |
|
GGT |
Six Sigma |
Six Sigma |
|
Glucose |
Six Sigma |
Six Sigma |
|
HDL |
Six Sigma |
Six Sigma |
|
LDL |
Six Sigma |
Six Sigma |
|
Magnesium |
Four Sigma |
- |
|
Phosphorous |
Four Sigma |
Six Sigma |
|
Potassium |
Six Sigma |
Six Sigma |
|
Protein, Total |
Six Sigma |
Six Sigma |
|
Sodium |
Four Sigma |
Four Sigma |
|
Triglycerides |
Five Sigma |
Six Sigma |
|
Urea Nitrogen |
Four Sigma |
Four Sigma |
|
Uric Acid |
Six Sigma |
Six Sigma |
Ramathibodi has also verified the Sigma metrics of its immunoassays.






Congratulations to Ramathibodi Hospital for expanding their verification and continuing to provide a world class standard of test results.